Home decoration needs to know these standard knowledge
Publish:2023-12-15 16:35:48 Source:New Lucky Stone Corporation (中菲传美)
Maybe you dont know that there are many "forbidden zones" in the decoration. These "forbidden areas" can not be demolished and destroyed in the process of decoration, otherwise it will destroy the integrity of the building and bring danger to you and your neighbors; while other parts of the room are "sensitive areas", youd better not make any changes, if you really need to change, you should invite professionals to construct.
Home Decoration "High Voltage Wire" 9 Sensitive Forbidden Areas Cant be Touched
1. Load-bearing wall: Load-bearing wall can not be demolished in decoration, as many people know. But what kind of wall is a load-bearing wall is not clear to many people. Generally, in "brick-concrete" structures, all prefabricated slab walls can not be demolished or opened doors and windows; brick walls over 24 cm are also load-bearing walls, and can not be demolished. The walls with "empty voice" are mostly non-load-bearing walls, which can be dismantled and altered.
In addition, some people open doors and windows on the load-bearing wall, which will also destroy the load-bearing wall, is not allowed.
If you want to dismantle the wall in the house in the decoration, it is better to ask the construction professionals to see if it is built after the load-bearing wall. Before the construction, it should also be reported to the property management department for the record, and the construction can be carried out only after approval.
2. Reinforcement in the wall: If the building structure is compared to the adult body, the reinforcement in the wall is the humans reinforcement. If the steel bar is destroyed when the pipeline is buried, the bearing capacity of the wall and floor will be affected. If there is an earthquake, such walls and floors can easily collapse or break.
3. Beams and columns in the room: These beams and columns are used to support the upper floor. When they are removed, the upper floor will fall down, so they can not move.
4. The low wall beside the balcony: There are doors and windows on the wall between the ordinary room and the balcony. These doors and windows can be dismantled, but the walls below them cant be moved. This wall is called "counterweight wall", which acts as a weighing board to provoke the balcony. Removal of this wall will reduce the bearing gravity of the balcony and cause the balcony to fall.
5. The doors of "three defenses" or "five defenses": The doorframes of these doors are embedded in concrete. If they are dismantled, they will destroy the building structure and reduce the safety factor. It also destroyed the building structure of the entrance, making it even more difficult to reinstall the new entrance.
6. Waterproof layer of bathroom and kitchen: There are waterproof layer under the ground in these places. If destroyed, downstairs will become "water curtain hole". So when you change the floor material, you must pay attention not to destroy the waterproof layer. If it is rebuilt after destruction, it is necessary to do "24-hour seepage experiment", that is, to irrigate in the kitchen or toilet. If it does not leak after 24 hours, it will be qualified.
7. The toilet squat toilet: Some old houses also use the old squat toilet, if you want to replace the toilet, you must be careful. Because squatting toilets are generally in front of the water, and toilets are generally in the back of the water, so changing toilets means changing the sewer pipeline. This kind of construction is difficult and must destroy the original waterproof layer. If installed improperly, either downstairs seepage, or toilet does not water.
8. Heating and gas pipelines: Installation and dismantling of gas pipelines must be carried out by the professional construction personnel of the gas company. Decoration companies cant "do it for you" and cant cover water meters, electricity meters and gas meters when decorating. For heating and heating pipes, you should also be cautious, because the position of heating in the indoor directly affects the indoor temperature in winter. If it is not properly dismantled, either heating is affected or heating runs out of water.
9. The original steel windows: Some households have replaced the aluminium alloy windows because the original steel windows are not good-looking. At present, some aluminium alloy windows are far less robust than steel windows, because a few decoration companies use small size profiles or simply sub-filling in order to get a cheaper picture.